Auto-Set® Model FSFD-TR
FIRE RATED
SMOKE RATED
VERTICAL ACTING
The Auto-Set® Model FSFD-TR is designed for use in areas where a Temperature Rise rating in addition to standard fire ratings is required.
Available with up to a 450° F over 30 minutes Temperature Rise rating when required, it meets building code requirements for fire doors used in exit enclosures and exit passageways of non-sprinklered buildings.
The Temperature Rise rated fire door model FSFD-TR is designed for openings where a temperature rise rating is a requirement such as in egress corridors, exit passageways and exit enclosures.
-
Up to 4-hour rated UL 10B*
Single assembly, 90-minute fire rating, available with a temperature rise rating of 650° over 30 minutes when required
Double assembly positioned back-to-back, 4-hour fire rating, available with a temperature rise rating of 450° over 30 minutes when required
Smoke & Draft labeled UL 1784
*Listed under the Canadian equivalent CAN/ULC S104
-
— CCRR-1086
-
Not applicable
-
Auto-Set® automatic resetting
Fail-Safe Design – automatic self-closing mechanism does not require power operation
Based upon door size, available with hand-chain or hand-crank operation
-
Unlimited heights and widths to 80′; for larger sizes and custom configurations consult the factory
-
McKEON Sterling Gray
Powder coat of any color as selected
Stainless steel — No. 4 Polish or No. 8 Mirror
![FSFD-TR-RadioShack-2O-768x603.jpg](https://images.squarespace-cdn.com/content/v1/648a66f74516f213d01c6c50/1724616868933-B8I9W84ZTSTCFWNFRURT/FSFD-TR-RadioShack-2O-768x603.jpg)
![FSFD-TR-RadioShack-2M-768x603.jpg](https://images.squarespace-cdn.com/content/v1/648a66f74516f213d01c6c50/1724616872882-B5DZP3E3J1WDJNTZ8J97/FSFD-TR-RadioShack-2M-768x603.jpg)
![FSFD-TR-RadioShack-2C-768x604.jpg](https://images.squarespace-cdn.com/content/v1/648a66f74516f213d01c6c50/1724616876521-18X4UECJD9WKZ85RAY31/FSFD-TR-RadioShack-2C-768x604.jpg)
![FSFD-TR-RadioShack-1O-768x581.jpg](https://images.squarespace-cdn.com/content/v1/648a66f74516f213d01c6c50/1724616908743-5QMI0ECKX44GCNAX4HXN/FSFD-TR-RadioShack-1O-768x581.jpg)
![FSFD-TR-RadioShack-1M-768x581.jpg](https://images.squarespace-cdn.com/content/v1/648a66f74516f213d01c6c50/1724616912026-8SMKQ5YS7PMMFTE9QWQV/FSFD-TR-RadioShack-1M-768x581.jpg)
![FSFD-TR-RadioShack-1C-768x581.jpg](https://images.squarespace-cdn.com/content/v1/648a66f74516f213d01c6c50/1724616915569-L481KTNP2R8DLTR9QE38/FSFD-TR-RadioShack-1C-768x581.jpg)
![FSFD-TR-RadioShack-3O-768x578.jpg](https://images.squarespace-cdn.com/content/v1/648a66f74516f213d01c6c50/1724616955380-CKS6D3IY737YG8JI0MWX/FSFD-TR-RadioShack-3O-768x578.jpg)
![FSFD-TR-RadioShack-3M1-768x578.jpg](https://images.squarespace-cdn.com/content/v1/648a66f74516f213d01c6c50/1724616959251-3PAZKZY228EXG6ISNJAM/FSFD-TR-RadioShack-3M1-768x578.jpg)
![FSFD-TR-RadioShack-3M2-768x578.jpg](https://images.squarespace-cdn.com/content/v1/648a66f74516f213d01c6c50/1724616963194-ROUKR3VLRDIZASG3FKYM/FSFD-TR-RadioShack-3M2-768x578.jpg)
![FSFD-TR-RadioShack-3C-768x578.jpg](https://images.squarespace-cdn.com/content/v1/648a66f74516f213d01c6c50/1724616971233-5NI1FEJOXEDNW45JZYJJ/FSFD-TR-RadioShack-3C-768x578.jpg)
![FSFD-TR-RadioShack-4O-768x570.jpg](https://images.squarespace-cdn.com/content/v1/648a66f74516f213d01c6c50/1724616997392-4PHSW7CDLDHEPBPD5U3P/FSFD-TR-RadioShack-4O-768x570.jpg)
![FSFD-TR-RadioShack-4M2-768x570.jpg](https://images.squarespace-cdn.com/content/v1/648a66f74516f213d01c6c50/1724617001563-XSYS7CID87M8S8BTXTIW/FSFD-TR-RadioShack-4M2-768x570.jpg)
![FSFD-TR-RadioShack-4M1-768x570.jpg](https://images.squarespace-cdn.com/content/v1/648a66f74516f213d01c6c50/1724617005491-INNXNFASYHTFGEVYT25B/FSFD-TR-RadioShack-4M1-768x570.jpg)
![FSFD-TR-RadioShack-4C-768x570.jpg](https://images.squarespace-cdn.com/content/v1/648a66f74516f213d01c6c50/1724617016603-TZETW96RNX5U2ZH4BQYZ/FSFD-TR-RadioShack-4C-768x570.jpg)
This technology is the subject of US Patent No. 8,453,707.